Safety Light Curtain MCS-4016-NJ
Safety Light Curtain, Safety Light Curtain MCS-4016-NJ
OVERALL HEIGHT(MM) : 700 MM
PROTECTED HEIGHT(MM) : 640 MM
NO OF BEAM: 16 BEAM
PITCH: 40 MM
output PNP or NPN/ NC
Output indications Through corresponding LEDs
Sensor Power Supply 12-24 volts DC
Response time On to off:10-15 msec.
Operating Temperature Up to 55 Degrees centigrade
Protections Output short circuit protected
Aluminium Cross Section 50X36 mm
Accessories Required Specifications:
To operate / working of Safety Light Curtain few more additional product may required for installation;ย we given a brief with product catalog link here
Controller forย safety Light Curtainย :
Power Supply Controller 220 VAC;
Relay Output ; 1 or 2 relay
Cable Set For Safety Light Curtain
Two Cables are Required for Installation
- Emitter cable length 5 Meter
- ย Reciever Cable Length 3 Meter
- with suitable Connectors at one End
Other Models in This Category: Safety Light Curtain MCS-4016-NJ
- Safety Light Curtain SLC-0630
- Safety Light Curtain SLC-0830
- Safety Light Curtain SLC-1030
- Safety Light Curtain SLC-1230
- Safety Light Curtain SLC-1630
- Safety Light Curtain SLC-1830
- Safety Light Curtain SLC-2430
- Safety Light Curtain SLC-3030
- As per Demand special orders
Technical Specifications: Safety Light Curtain MCS-4016-NJ
Sensor Power Supplyย : 12-24 volts DC
outputย ; PNP or NPN/ NC
Output indications ; Through corresponding LEDs
Response time On to off : 10-15 msec.
No of beams : 8,10,12,16, 18, 24, 30, or as required
Beam bypass Provided in Controller
Adjustable Range Up to 3 meters
Higher Sensing range up to 5,10,15 meter. available on demand
Standard Cable length 5 meters for the emitter, 3 meters for the receiver
Operating Temperature Up to 55 Degrees centigrade
Protections Output short circuit protected
Suitable for Machines with quick emergency stop
FEATURES:-
An ISO 9001:2015 Certified Company, 2 Outputs model also available,
Safety Light curtains must comply with IEC-61496 parts 1 & 2 ; as ANSI/UL 61496 parts 1 & 2. Light curtains’ “TYPE” their Safety Performance Level, must be appropriately selected. Light curtains’ optional functions, as listed in Annex “A” of IEC-61496 part 1, must comply with Annex “A” requirements.
working Principle:
A safety light curtain consists of two parts: Transmitter + Receiver. – The transmitter contains multiple Infrared LEDs that send pulses of infrared light to the receiver. When an interrupt occurred between the transmitter and receiver then we receive an output that used to stop working or raise alarm.
Join Us as Business Partner / Dealer / Stockist in Your City Send yourย Proposal / offer to us. Your efforts will be highly appreciated.
Reviews